Variant: 1Female with clinically insignificant breast pain (nonfocal [greater than one quadrant], diffuse, or cyclical) without other suspicious clinical finding. Any age. Initial imaging.
Procedure
Appropriateness Category
US breast
Usually Not Appropriate
Digital breast tomosynthesis diagnostic
Usually Not Appropriate
Mammography diagnostic
Usually Not Appropriate
MRI breast without and with IV contrast
Usually Not Appropriate
MRI breast without IV contrast
Usually Not Appropriate
Sestamibi MBI
Usually Not Appropriate
Variant: 2Female with clinically significant breast pain (focal and noncyclical). Age less than 30. Initial imaging.
Procedure
Appropriateness Category
US breast
Usually Appropriate
Digital breast tomosynthesis diagnostic
Usually Not Appropriate
Mammography diagnostic
Usually Not Appropriate
MRI breast without and with IV contrast
Usually Not Appropriate
MRI breast without IV contrast
Usually Not Appropriate
Sestamibi MBI
Usually Not Appropriate
Variant: 3Female with clinically significant breast pain (focal and noncyclical). Age 30 to 39. Initial imaging.
Procedure
Appropriateness Category
US breast
Usually Appropriate
Digital breast tomosynthesis diagnostic
Usually Appropriate
Mammography diagnostic
Usually Appropriate
MRI breast without and with IV contrast
Usually Not Appropriate
MRI breast without IV contrast
Usually Not Appropriate
Sestamibi MBI
Usually Not Appropriate
Variant: 4Female with clinically significant breast pain (focal and noncyclical). Age greater than or equal to 40. Initial imaging.
Procedure
Appropriateness Category
US breast
Usually Appropriate
Digital breast tomosynthesis diagnostic
Usually Appropriate
Mammography diagnostic
Usually Appropriate
MRI breast without and with IV contrast
Usually Not Appropriate
MRI breast without IV contrast
Usually Not Appropriate
Sestamibi MBI
Usually Not Appropriate
The evidence table, literature search, and appendix for this topic are available at https://acsearch.acr.org/list. The appendix includes the strength of evidence assessment and the final rating round tabulations for each recommendation.
The imaging procedure or treatment is indicated in the specified clinical scenarios at a favorable risk-benefit ratio for patients.
May Be Appropriate
4, 5, or 6
The imaging procedure or treatment may be indicated in the specified clinical scenarios as an alternative to imaging procedures or treatments with a more favorable risk-benefit ratio, or the risk-benefit ratio for patients is equivocal.
May Be Appropriate (Disagreement)
5
The individual ratings are too dispersed from the panel median. The different label provides transparency regarding the panel’s recommendation. “May be appropriate” is the rating category and a rating of 5 is assigned.
Usually Not Appropriate
1, 2, or 3
The imaging procedure or treatment is unlikely to be indicated in the specified clinical scenarios, or the risk-benefit ratio for patients is likely to be unfavorable.
The ACR Committee on Appropriateness Criteria and its expert panels have developed criteria for determining appropriate imaging examinations for diagnosis and treatment of specified medical condition(s). These criteria are intended to guide radiologists, radiation oncologists and referring physicians in making decisions regarding radiologic imaging and treatment. Generally, the complexity and severity of a patient’s clinical condition should dictate the selection of appropriate imaging procedures or treatments. Only those examinations generally used for evaluation of the patient’s condition are ranked. Other imaging studies necessary to evaluate other co-existent diseases or other medical consequences of this condition are not considered in this document. The availability of equipment or personnel may influence the selection of appropriate imaging procedures or treatments. Imaging techniques classified as investigational by the FDA have not been considered in developing these criteria; however, study of new equipment and applications should be encouraged. The ultimate decision regarding the appropriateness of any specific radiologic examination or treatment must be made by the referring physician and radiologist in light of all the circumstances presented in an individual examination